Multiphase Reactors Engineering and Applications Laboratory performed gas phase dispersion experiments in a separate-effect cold-flow experimental setup for coolant flow within heated channels of the prismatic modular reactor under accident scenario using gaseous tracer technique. The separate-effect experimental setup was designed on light of local velocity measurements obtained by using hot wire anemometry. The measurements consist of pulse-response of gas tracer that is flowing through the mimicked riser channel using air as a carrier. The dispersion of the gas phase within the separate-effect riser channel was described using one-dimensional axial dispersion model. The axial dispersion coefficient and Peclet number of the coolant gas phase and their residence time distribution within were measured. Effect of heating intensities in terms of heat fluxes on the coolant gas dispersion along riser channels were mimicked in the current study by a certain range of volumetric air flow rate ranging from 0.0015 to 0.0034 m3/s which corresponding to heating intensity range from 200 to 1400 W/m2. Results confirm a reduction in the response curve spreads is achieved by increasing the volumetric air velocity (representing heating intensity). Also, the results reveal a reduction in values of axial dispersion coefficient with increasing the air volumetric flow rate.