We performed aspiration of early pregnancy on 100 women requesting termination, using a low caliber angled catheter under sonographic guidance, without analgesia or anesthesia. The sonographic inclusion criteria for the study were: (1) mean gestational sac diameter less than 30 mm, or (2) crown rump length less than 10 mm when an embryo was visualized. The uterine content was successfully evacuated in all cases and none needed an additional curettage. Two women developed mild endometritis which responded to antibiotic therapy. This refinement of this 'menstrual regulation' technique seems to be safer when compared with the reported results of the original technique.