Experimental model of Pseudomonas aeruginosa biofilm was established in vitro by using biofilm reactor. The aim of this study was evaluating the removal effect of two kinds of water flowing through bactericide resin on Pseudomonas aeruginosa biofilm, and exploring the effectiveness of continuous treatment with low concentration disinfection factor on dental unit waterlines. The experimental group selected 1-2 mg/L iodinated resin (IR) filtered water and bromined hydantoin resin (BHR) filtered water with the control group selecting the sterile distilled water. Biofilms were treated by using the immersion method for 3, 7, 10, 20, and 40 days. Total viable count (TVC) and laser confocal microscopy method (CLSM) were selected to evaluate the biofilm removal effect. The result of TVC showed that in group IR, the bacterial clearance after the treatment of 3, 7, 10, and 20 days was lower than 99.9% and unqualified. The bacterial clearance after the treatment of 40 days was 99.9%,which is qualified. In group BHR, it was lower than 99.9% and unqualified after the treatment of 3, 7, and 10 days. It was and 99.99%, 100.00% after the treatment of 20, 40 days, respectively. The result of CLSM showed that before treatment, Pseudomonas aeruginosa biofilm showed a sheet and mass distribution. The bacterial coverage was 19.24%±1.97%. The proportion of viable bacteria was 93.91%±1.39%, and the biofilm matrix coverage was 17.69%±1.11%. After 20 days of treatment, the biofilm was decreased in the IR group, with the biofilm bacterial coverage reducing to 6.77%±1.61%, the proportion of live bacteria reducing to 54.85%±5.65%, and the biofilm matrix coverage reducing to 2.41%±0.85%.There was significant difference from the pre-treatment and the control (F=359.996,P<0.001). No biofilm-like structure was found in the BHR group. After 40 days of treatment, there was still a small amount of biofilm matrix residue in the IR group, with no bacterial coverage observed. The biofilm matrix coverage was 0.67%±0.47% (F=1 021.373,P<0.001). No biofilm-like structure was found in the BHR group. In conclusion, the continuous application of BHR filter water has more advantages in killing microorganisms in biofilms, removing live and dead bacteria and biofilm matrix in biofilms. Treatment water containing corresponding low concentration disinfection factors can play an important role in the field of biofilm control in dental unit waterlines.
Read full abstract