BackgroundTranscatheter aortic valve replacement has become a routine procedure for patients with severe symptomatic aortic stenosis at increased surgical risk. Not much is known about using prophylactic support with venoarterial extracorporeal membrane oxygenation in patients undergoing transcatheter aortic valve replacement and eventually concomitant complex percutaneous coronary intervention.Case presentationWe present a successful procedure of transcatheter aortic valve replacement and high-risk percutaneous coronary intervention utilizing venoarterial extracorporeal membrane oxygenation for hemodynamic support in a very frail 88-year-old Caucasian woman with severe symptomatic aortic stenosis and coronary bypass grafting in the past.Echocardiography revealed a “low-flow low-gradient” aortic stenosis (mean transvalvular gradient 30 mmHg, aortic valve area 0.4 cm2, significant calcification), a left ventricular ejection fraction of 35%, severe mitral regurgitation with moderate stenosis (mean transvalvular gradient 7 mmHg), with a systolic pulmonary artery pressure of 80 mmHg. Moreover, pre-interventional coronary angiography exposed a severe left main ostial stenosis and sequential subtotal heavily calcified stenosis of the left anterior descending artery . Computed tomographic angiography showed no heavy tortuosity but moderate calcification of the iliofemoral arteries.The procedure was performed under general anesthesia in our hybrid operating room. Extracorporeal membrane oxygenation was established by left femoral percutaneous cannulation using a 21-Fr venous and 15-Fr arterial cannula. Subsequently, complex percutaneous coronary intervention with implantation of two drug-eluting stents from the left main into the left anterior descending artery was performed via a right femoral arterial 7F sheath. Thereafter, a 23-mm Sapien 3 aortic valve prosthesis (Edwards, Irvine, CA, USA) was implanted via right femoral artery in the usual manner, whereby the arterial pigtail catheter for marking the aortic annulus during transcatheter aortic valve replacement was inserted over a Check-Flo® Hemostasis Assembly (Cook Medical, Bloomington, IN, USA) on a Y-adapter via the arterial extracorporeal membrane oxygenation cannula. After extracorporeal membrane oxygenation decannulation, vascular closure was easily performed using the MANTA vascular closure device in order to reduce procedural time and risk of access site complications.ConclusionsIn summary, we demonstrate the feasibility of elective prophylactic extracorporeal membrane oxygenation implementation in selected very high-risk and frail patients undergoing transcatheter aortic valve replacement and percutaneous coronary intervention in order to avoid intraprocedural complications.
Read full abstract