During the 2009 experimental campaign the Edge Thomson Scattering System started the operations, after a commissioning period. The main modification has been the adoption of interferential filters spectrometers with APD detectors, similar to those used on the main TS. Other improvements were the optimization of the laser input path and of the collection optics, which increased the signal level of about 50 %.With the present setup, temperature and density measures show good compatibility with those of the main TS diagnostic; density data have been calculated after Rotational Raman Scattering calibration, a method which is not affected by impurity deposition on the collection window. Present operational limits of the diagnostic are discussed as well as short terms planned operations, focusing in particular on laser multi-pulse issues and laser sharing with the impurity injection system by laser blow-off.