We aimed to evaluate the safety and efficacy of fluoroscopically placed jejunal extension tubes (J-arm) in patients with existing gastrostomy tubes. We conducted a retrospective review of 391 J-arm placements performed in 174 patients. Indications for jejunal nutrition were aspiration risk (35%), pancreatitis (17%), gastroparesis (13%), gastric outlet obstruction (12%), and other (23%). Technical success, complications, malfunctions, and patency were assessed. Percutaneous gastrostomy (PEG) tube location, J-arm course, and fluoroscopy time were correlated with success/failure. Failure was defined as inability to exit the stomach. Procedure-related complications were defined as adverse events related to tube placement occurring within seven days. Tube malfunctions and aspiration events were recorded and assessed. Technical success was achieved in 91.9% (95% CI, 86.7%-95.2%) of new tubes versus 94.2% (95% CI, 86.7%-95.2%) of replacements (P = 0.373). Periprocedural complications occurred in three patients (0.8%). Malfunctions occurred in 197 patients (50%). Median tube patency was 103 days (95% CI, 71-134 days). No association was found between successful J-arm placement and gastric PEG tube position (P = 0.677), indication for jejunal nutrition (P = 0.349), J-arm trajectory in the stomach and incidence of malfunction (P = 0.365), risk of tube migration and PEG tube position (P = 0.173), or J-arm length (P = 0.987). A fluoroscopy time of 21.3 min was identified as a threshold for failure. Malfunctions occurred more often in tubes replaced after 90 days than in tubes replaced before 90 days (P < 0.001). A total of 42 aspiration events occurred (OR 6.4, P < 0.001, compared with nonmalfunctioning tubes). Fluoroscopy-guided J-arm placement is safe for patients requiring jejunal nutrition. Tubes indwelling for longer than 90 days have higher rates of malfunction and aspiration.
Read full abstract