In an effort to expedite the publication of articles, AJHP is posting manuscripts online as soon as possible after acceptance. Accepted manuscripts have been peer-reviewed and copyedited, but are posted online before technical formatting and author proofing. These manuscripts are not the final version of record and will be replaced with the final article (formatted per AJHP style and proofed by the authors) at a later time. Central line-associated bloodstream infections (CLABSIs) are hospital-acquired, serious complications that greatly affect many vulnerable neonates throughout their hospital stay. This article describes the implementation of a unique practice in which pharmacy primes continuous infusions through medication tubing for neonatal central lines in a cleanroom at Children's Hospital Colorado - Colorado Springs (CHCO-CSH). This institution is a freestanding children's hospital with a level III neonatal intensive care unit (NICU) that opened in April 2019. Since then, the pharmacy department has been priming central line tubing for continuous infusions for all patients in the NICU. Neonates are at increased risk for developing CLABSIs due to their immature immune systems and frequent need for central line placement. With that in mind, the pharmacy department decided to focus efforts on this population. Pharmacists and pharmacy technicians received training on how to properly prime tubing, document when a patient received a new central line, document if a central line was removed, and record when new tubing was due based on a department policy. This novel, pharmacy-led priming procedure resulted in a low CLABSI incidence, offering a promising strategy to reduce CLABSIs in a NICU.