The relationship between in vivo behavior and in vitro characteristics of 59 platelet concentrates (PC) stored for up to 14 days in a synthetic medium or in CPDA-1 plasma was systematically investigated. 25 paired studies (1 study was incomplete) were performed comparing platelets suspended either in the synthetic medium or CPDA-1 plasma with 5 days (n = 5); 7 days (n = 10); 10 days (n = 5); and 14 days (n = 5) of storage. In addition, 10 control studies were performed with freshly prepared PC (6-24 h) in CPDA-1 plasma. Both percent recovery and survival estimations showed decreases with increasing storage duration, irrespective of storage medium used. In both media, with prolonged storage, the platelet survival curves not only became shorter, but also increasingly exponential, suggesting that in vitro storage caused progressive damage to the platelets present in circulation. Survival curves of platelets suspended in synthetic medium remained more linear, indicative of less random damage during storage. Mean population lifespan (MPL) of the stored PC was determined by the area below the survival curve divided by the mean percent recovery for the fresh PC, which was 55%. MPL decreased from 4.5 days (fresh PC) to 0.4 days after 14 days of storage in plasma, with a 50% reduction (t1/2) estimated at 7.2 days of storage. MPL t1/2 for PC stored in the synthetic medium was estimated to be 8.8 days.(ABSTRACT TRUNCATED AT 250 WORDS)