In this protocol, we outline procedures to mount the fly and to open up the head cuticle to expose the optic lobes for in vivo imaging. The fly is first inserted into a custom-made fly chamber in which the fly's head is stabilized on a piece of aluminum foil. Once the fly is mounted in the chamber, its head cuticle is removed, exposing the optic lobe for recording. The brain tissues (above the foil), including the optic lobes, should be bathed in fly saline. Meanwhile, the eyes (below the foil) are kept dry to receive light stimuli during the recording. A considerable level of expertise and hand dexterity is required to handle a small animal such as a fly, especially when opening its head capsule without damaging the brain tissue. This expertise should be gained through mindful repetition of the protocol. With appropriate preparation and skills, the success rate for this procedure can be >95%. Using this protocol, it is possible to record ultraviolet (UV)-sensing photoreceptors, which have long visual fibers that terminate at the medulla (the second optic neuropil). Depending on the visual neurons of interest, some modifications to fly mounting might be needed.