BackgroundReirradiation of head and neck cancer (HNC) became more accessible in the last decade, owing to modern irradiation techniques which offer a reduction in treatment related toxicities. The aim of this paper was to comparatively evaluate the dosimetric aspects derived from intensity modulated photon vs. proton treatment planning in reirradiated HNC patients. MethodsSix recurrent HNC patients were enrolled in this retrospective study. For each patient two treatment plans were created: one IMRT/VMAT and one IMPT plan. The prescribed dose for the second irradiation was between 50 and 70 Gy RBE. The study comparatively analyzed the CTV coverage, doses to organs at risk (OARs) and low doses received by the healthy tissue (other than OAR). ResultsSimilar CTV coverage was achieved for photon vs proton plans, with the latter presenting better homogeneity in four cases. Maximum dose to CTV was generally higher for photon plans, with differences ranging from 0.3 to 1.9%. For parotid glands and body, the mean dose was lower for proton plans. A notable reduction of low dose to healthy tissue (other than OARs) could be achieved with protons, with an average of 60% and 64% for D10% and Dmean, respectively. ConclusionThe dosimetric comparison between photon and proton reirradiation of HNC showed a great need for treatment individualization, concluding that protons should be considered for reirradiation on an individual basis.