The paper focuses on the interphase force of the gas-liquid two-phase flow in the horizontal pipe design and designs a new interpahse force quantitative detection devices. On the basis of analyzing the physical models and the mathematical models, the devices got the more accurate differential pressure and the two-phase flow phase holdup, avoiding many factors by using the capacitance sensor which is made up of the complete closure outer electrode and flow media as the inner electrode. Finally, the devices achieved the quantitative detection of the interphase force through the differential pressure and the phase holdup. The experiments proved that the devices can better reflect the interphase force changes of the gas-liquid two-phase flow in the horizontal tube and reached the design goal very well.