This article is concerned with the fault detection and isolation (FDI) problem for a class of nonlinear systems described by the T–S fuzzy models. Based on the concept of minimum unobservability subspace and geometric property of factor space, a set of FDI filters where each residual is only affected by one fault and completely decoupled from other faults is designed. Furthermore, in the decoupling space, the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$H_{\infty }/H_{-}$ </tex-math></inline-formula> performance indexes are provided to enhance the sensitivity of residual to faults and robustness to disturbances. In particular, to solve the nonconvex filter design problem caused by introducing the <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"> <tex-math notation="LaTeX">$H_{-}$ </tex-math></inline-formula> index, the Gerschgorin theorem is first used to linearize the corresponding filter design conditions in the outer region of a ball. Then, the FDI filter design problem is converted into a convex optimization one, which is solved via the linear matrix inequality (LMI) control Toolbox, and the advantages and effectiveness of the proposed FDI method are verified through two simulation examples.