To derive systematic-review informed, modified Delphi consensus regarding the influence of extracorporeal membrane oxygenation (ECMO) circuit components on anticoagulation practices for pediatric ECMO for the Pediatric ECMO Anticoagulation CollaborativE. A structured literature search was performed using PubMed, EMBASE, and Cochrane Library (CENTRAL) databases from January 1988 to May 2021. Management of ECMO anticoagulation in the setting of different ECMO circuit components. Two authors reviewed all citations independently, with a third independent reviewer resolving conflicts. Twenty-nine references were used for data extraction and informed recommendations, evidence-based consensus statements, and good practice statements. Evidence tables were constructed using a standardized data extraction form. Risk of bias was assessed using the Quality in Prognosis Studies tool. The evidence was evaluated using the Grading of Recommendations Assessment, Development and Evaluation system. Forty-eight experts met over 2 years to develop evidence-based recommendations and, when evidence was lacking, expert-based consensus statements or good practice statements for the influence of ECMO circuit and components on anticoagulation management. A web-based modified Delphi process was used to build consensus via the Research And Development/University of California Appropriateness Method. Consensus was defined as greater than 80% agreement. One good practice statement, 2 weak recommendations, and 2 consensus statements are presented. The incorporation of new component technologies into clinical practice has outpaced clinical investigations of anticoagulation strategies for pediatric ECMO. Future investigations should leverage academic and industrial collaborations, translational platforms, and modern biostatistical methods to improve patient outcomes.