Abstract Funding Acknowledgements Type of funding sources: None. Background The influence of the external counterpulsation (ECP, EECP) on patients with diastolic dysfunction of the left ventricle (LV) is unclear. We aim to determine whether external counterpulsation therapy improves echocardiographic parameters in these patients. Methods We studied 57 patients with stable coronary artery disease undergoing one course of external counterpulsation therapy. The average age of the patients was 63.07 ± 7.44 years (there were 43 (75.4%) male and 14 (24.6%) women). All patients divided into two groups: patients with diastolic dysfunction of the left ventricle (E/e" ratio > 14, total 15 patients, main group) and control group (E/e"< =14, total 42 patients). The mean age of the patients included in the main and control groups was 64.20 ± 5.93 and 62.67 ± 7.93 years (p = 0.36). All patients treated with one course of ECP (EECP) treatment (33,26 ± 3,60 and 32,85 ± 4,56 sessions, p = 0,38). Results from echocardiographic examinations after the treatment in these groups were compared. Echocardiographic assessment included evaluation of the chamber size, chamber volume, ejection fraction of the left ventricle (LV) by 2D and Doppler measurements. Results Echocardiographic parameters for main and control groups before treatment: the diastolic diameter of the LV (cm): 5,65 ± 0,97 and 5,20 ± 0,62 (p = 0,0913); the end-diastolic volume of the LV (ml): 93.53 ± 28.38 and 75.45 ± 25.13 (p = 0.0163); LV stroke volume (ml): 48,57 ± 11,47 and 43,02 ± 10,64 (p = 0,1471); LV ejection fraction (%): 52.83 ± 10.12 and 59.11 ± 9.53 (p = 0.0340); the volume of the left atrium (ml): 73.25 ± 22.79 and 57.86 ± 20.60 (p = 0.0229); tissue Doppler velocity of the mitral annulus (e ", cm/s): 5,89 ± 1,18 and 7,43 ± 1,50 (p = 0,0006); E/e" ratio: 18,85 ± 3,40 and 9,69 ± 1,95 (p < 0,0001). Echocardiographic parameters for the main and control groups after treatment: the diastolic diameter of the LV (cm): 5.53 ± 0.85 and 5.15 ± 0.57 (p = 0.1879); the end diastolic volume of the LV (ml): 92.91 ± 31.29 and 75.15 ± 22.78 (p = 0.0536); LV stroke volume (ml): 50,77 ± 11,49 and 47,01 ± 11,24 (p = 0,2612); LV ejection fraction (%): 56.81 ± 10.50 and 64.06 ± 7.67 (p = 0.0088); the volume of the left atrium (ml): 60.84 ± 16.20 and 55.77 ± 17.53 (p = 0.2388); tissue Doppler velocity of the mitral annulus (e", cm/s): 6,15 ± 1,11 and 7,73 ± 1,90 (p = 0,0037); E/e" ratio: 15.97 ± 5.39 and 10.08 ± 2.81 (p < 0.0001). Statistically significant changes between two groups noted for the left atrium volume: decrease in 12,41 ± 16,33 ml and 2,09 ± 13,72 ml (p = 0,0124) in both groups, and for E/e" ratio: decrease in -2,87 ± 3,94 in the main group and increase in 0,39 ± 2,12 in the control group (p = 0,0003). Conclusion ECP treatment was associated with a decrease in the left atrium volume and E/e’ ratio in patients with diastolic dysfunction of the left ventricle.