The encroachment of selective chemical vapor deposition of tungsten at the edge of contacts has been examined with RBS, SEM, stylus height measurements, and TEM. Encroachment is minimized by using reduction instead of reduction, a deposition temperature of 340°C or less, an in situ plasma clean, and a flow ratio ≥0.1. Use of a plasma clean can reduce the W grain size by a factor of four and reduce nonuniform consumption of the polysilicon. The improvements using a plasma clean are associated with an increase in the density of chemical vapor deposition of tungsten nucleation sites.