Simple SummaryThis study outlines the authors’ experience using the Amplatzer Vascular Plug II device for occlusion of patent ductus arteriosus (PDA) in dogs through a right transjugular approach, never before described in veterinary medicine for this purpose. The obtained results demonstrate that the use of the Amplatzer Vascular Plug II via a transvenous right jugular approach is a feasible and effective method, even in small-sized patients. The authors’ experience is that the transvenous approach is a safe and effective method for PDA occlusion in dogs. Furthermore, the right jugular approach provides easier and faster vascular access than the femoral one. The authors affirm that this approach, together with the properties of the Amplatzer Vascular Plug II and its wide size selection, potentially provide a novel method that can complement the current available methods for transcatheter PDA occlusion.Although vascular plugs for the closure of patent ductus arteriosus (PDA) have been validated in dogs, studies are lacking on its use as a first-choice device with a transjugular approach. The present case series describes the transvenous right jugular embolization of PDA using an Amplatzer Vascular Plug II in seven dogs of different ages, breeds, and body weights. Complete closure of the PDA was demonstrated in all cases. All dogs showed significant hemodynamic reduction of pulmonary overcirculation and left heart size after the procedure and at following echocardiographic check-ups. Transjugular PDA occlusion using an Amplatzer Vascular Plug II can thus be considered as a safe alternative to the arterial or venous femoral approach using an Amplatzer canine ductal occluder (ACDO), particularly in puppies with small femoral vessels.