The internal pressure evolution of cylindrical lithium-ion battery cells under abuse tests is evaluated in this work. The pressure evolution is recorded through a cavity at the center of the inner structure of the cylindrical cell. Understanding pressure buildup due to exothermic reactions aids in designing safety features, such as improved venting mechanisms. The pressure activation for the safety mechanism depends on both the venting cap design and the different abuse test conditions. This study focuses on two important parameters: the state of charge (SOC) and the overheating ramp. The SOC significantly influences the venting pressure activation at the overheating abuse tests. The 18650 cell exhibits a similar venting behavior as the 21700 cell, with pressure safety mechanisms activating sooner for the 18650 cell. The geometric structure of the battery and safety mechanisms significantly influence vent-activation thresholds. After the Current Interruptor Device (CID) breakdown, pressure rises exponentially until venting occurs, due to gas generation from the decomposition of internal components and electrolyte vaporization. With the experimental data for the overheating abuse test, a model that predicts the evolution of the pressure has been developed. For the overcharging abuse test, the pressure evolution has been measured with different current rates (C-rates) to simulate overcharge with standard charging current and fast charging current. However, the internal pressure inside the cell activates the current interrupt device, which avoids overcharging the cell, thus preventing the thermal runaway (TR) from occurring.
Read full abstract