To investigate the effectiveness of a new tibial plateau posterolateral column universal locking anatomical plate (hereinafter referred to as "new universal locking anatomical plate") in the treatment of tibial plateau posterolateral column fractures. Between October 2020 and December 2021, 14 patients with tibial plateau posterolateral column fracture were treated with a new universal locking anatomical plate. There were 7 males and 7 females with an average age of 59 years ranging from 29 to 75 years. There were 5 cases on the left side and 9 cases on the right side. The causes of injury included falling from height in 5 cases, traffic accident in 7 cases, and other injuries in 2 cases. The time from injury to operation ranged from 3 to 10 days, with an average of 6 days. According to Schatzker classification, there were 4 cases of type Ⅱ, 8 cases of type Ⅴ, and 2 cases of type Ⅵ. All fractures involved the posterolateral tibial plateau. Three column classification: two columns (anterolateral column+posterior column) in 4 cases, three columns in 10 cases. The operation time, intraoperative blood loss, fracture healing, and complications were recorded. The reduction of tibial plateau fracture was evaluated by Rasmussen radiographic score, and the recovery of knee function was evaluated by Hospital for Special Surgery (HSS) score. All 14 cases completed the operation successfully. The operation time was 95-180 minutes, with an average of 154 minutes, and the intraoperative blood loss was 100-480 mL, with an average of 260 mL. All patients were followed up 6-19 months, with an average of 12.5 months. All fractures healed, and the healing time was 15-24 weeks, with an average of 18.7 weeks. During the follow-up, there was 1 case of common peroneal nerve palsy and 1 case of traumatic osteoarthritis. There was no other complication such as vascular injury, incision infection, deep venous thrombosis of lower limbs, heterotopic ossification, bone nonunion, and failure of internal fixation. The reduction of tibial plateau fractures was good immediately after operation, and the Rasmussen radiological score was 10-18, with an average of 15.7; 3 cases were excellent, 10 cases were good, and 1 case was fair, with an excellent and good rate of 92.9%. The scores and grades of HSS at 3 months after operation and at last follow-up significantly improved when compared with those before operation ( P<0.05). There was no significant difference between 3 months after operation and last follow-up ( P>0.05). For the fractures involving the posterolateral column of the tibial plateau, the new universal locking anatomical plate can provide strong fixation, satisfactory postoperative fracture reduction, and good recovery of knee function.