BackgroundStudies on consistency among spirometry, impulse oscillometry (IOS), and histology for detecting small airway dysfunction (SAD) remain scarce. Considering invasiveness of lung histopathology, we aimed to compare spirometry and IOS with chest computed tomography (CT) for SAD detection, and evaluate clinical characteristics of subjects with SAD assessed by these three techniques.MethodsWe collected baseline data from the Early COPD (ECOPD) study. CT-defined SAD was defined as parametric response mapping quantifying SAD (PRMfSAD) ≥ 15%. Spirometry-defined SAD was defined as at least two of maximal mid-expiratory flow (MMEF), forced expiratory flow 50% (FEF50), and forced expiratory flow 75% (FEF75) less than 65% of predicted. IOS-defined SAD was defined as peripheral airway resistance R5 − R20 > 0.07 kPa/L/s. The consistency of spirometry, IOS and CT for diagnosing SAD was assessed using Kappa coefficient. Correlations among the three techniques-measured small airway function parameters were assessed by Spearman correlation analysis.Results2055 subjects were included in the final analysis. There was low agreement in SAD assessment between spirometry and CT (Kappa = 0.126, 95% confidence interval [CI]: 0.106 to 0.146, p < 0.001), between IOS and CT (Kappa = 0.266, 95% CI: 0.219 to 0.313, p < 0.001), as well as among spirometry, IOS, and CT (Kappa = 0.056, 95% CI: 0.029 to 0.082, p < 0.001). The correlation was moderate (|r|: 0.5 to 0.7, p < 0.05) between spirometry and CT-measured small airway function parameters, and weak (|r|< 0.4, p < 0.05) between IOS and CT-measured small airway function parameters. Only spirometry-defined SAD group had more lower lung function (FEV1/FVC: adjusted difference=-10.7%, 95% CI: -13.5% to -7.8%, p < 0.001) and increased airway wall thickness (Pi 10: adjusted difference = 0.3 mm, 95% CI: 0 to 0.6 mm, p = 0.046) than only CT-defined SAD group. Only IOS-defined SAD group had better lung function (FEV1/FVC: adjusted difference = 3.9%, 95% CI: 1.9 to 5.8%, p < 0.001), less emphysema (inspiratory LAA− 950: adjusted difference=-2.1%, 95% CI:-3.1% to -1.1%, P < 0.001; PRMEmph: adjusted difference=-2.3%, 95% CI: -3.2% to -1.4%, p < 0.001), and thicker airway wall (Pi 10: adjusted difference = 0.2 mm, 95% CI: 0.1 mm to 0.4 mm, p = 0.005) than only CT-defined SAD group.ConclusionsThere was low consistency in the assessment of SAD between spirometry and CT, between IOS and CT, as well as among spirometry, IOS, and CT.Clinical trial numberNot applicable.
Read full abstract