Objectives: To investigate the outcomes of cochlear implantation in Mandarin-speaking cochlear implant (CI) users with single-sided deafness (SSD). Methods: This study was a single-center prospective cohort study. Eleven Mandarin-speaking adult SSD patients who underwent CI implantation at Capital Medical University Beijing Tongren Hospital from August 2020 to October 2021 were recruited, including 6 males and 5 females, with the age ranging from 24 to 50 years old. In a sound field with 7 loudspeakers distributed at 180°, we measured root-mean-square error(RMSE)in SSD patients at the preoperative, 1-month, 3-month, 6-month, and 12-month after switch-on to assess the improvement of sound source localization. The Mandarin Speech Perception (MSP) was used in the sound field to test the speech reception threshold (SRT) of SSD patients under different signal-to-noise locations in a steady-state noise under conditions of CI off and CI on, to reflect the head shadow effect(SSSDNNH), binaural summation effect(S0N0) and squelch effect(S0NSSD). The Tinnitus Handicap Inventory (THI) and the Visual Analogue Scale (VAS) were used to assess changes in tinnitus severity and tinnitus loudness in SSD patients at each time point. The Speech, Spatial and Qualities of Hearing Scale(SSQ) and the Nijmegen Cochlear Implantation Scale (NCIQ) were used to assess the subjective benefits of spatial speech perception and quality of life in SSD patients after cochlear implantation. SPSS 19.0 software was used for statistical analysis. Results: SSD patients showed a significant improvement in the poorer ear in hearing thresholds with CI-on compared with CI-off; The ability to localize the sound source was significantly improved, with statistically significant differences in RMSE at each follow-up time compared with the preoperative period (P<0.05). In the SSSDNNH condition, which reflects the head shadow effect, the SRT in binaural hearing was significantly improved by 6.5 dB compared with unaided condition, and the difference was statistically significant (t=6.25, P=0.001). However, there was no significant improvement in SRT between the binaural hearing condition and unaided conditions in the S0N0 and S0NSSD conditions (P>0.05). The total score of THI and three dimensions were significant decreased (P<0.05). Tinnitus VAS scores were significantly lower in binaural hearing compared to the unaided condition (P<0.001). The total score of SSQ, and the scores of speech and spatial dimensions were significant improved in binaural hearing compared to the unaided condition (P<0.001). There was no statistical difference in NCIQ questionnaire scores between preoperative and postoperative (P>0.05), and only the self-efficacy subscore showed a significant increase(Z=-2.497,P=0.013). Conclusion: CI could help Mandarin-speaking SSD patients restore binaural hearing to some extent, improve sound localization and speech recognition in noise. In addition, CI in SSD patients could suppress tinnitus, reduce the loudness of tinnitus, and improve subjective perceptions of spatial hearing and quality of life.