We determined the factors influencing total capsule colonoscopy, adequate cleansing, and detectability of second-generation colon capsule endoscopy (CCE) for colorectal polyps or tumors (CRTs), adverse events, and acceptability. Among 44 Japanese hospitals, 1,006 patients with suspected or documented colorectal diseases who underwent CCE were enrolled prospectively. The total capsule colonoscopy rate was 86.1%. Age younger than 63 years (adjusted odds ratio [aOR], 1.525), male sex (aOR, 1.496), inflammatory bowel disease (aOR, 1.889), lavage intake on Day -1 (aOR, 1.625), ≥1800 mL lavage intake on Day 0 (aOR, 0.595), prokinetics on Day 0 (aOR, 0.608), and ≥30 mL castor oil booster on Day 0 (aOR, 1.734) were significant independent predictors. The overall adequate cleansing rate was 65.5%. Constipation (aOR, 0.527), lavage intake on Day -1 (aOR, 1.822), laxative intake on Day -1 (aOR, 2.616), and ≥1900 mL lavage intake on Day 0 (aOR, 1.449) were significant independent predictors. The detection rates (95% confidence intervals) for patients with CRTs ≥6 mm and ≥10 mm were 92 (84-97) % and 89 (78-96) %, respectively. Inadequate cleansing in the ascending colon (aOR, 0.184), ≥6 mm CRT in the transverse colon (aOR, 4.703), and ≥6 mm CRT in the left-sided colon (aOR, 32.013) were significant independent predictors. CCE retention occurred in two patients (0.20%) requiring endoscopic and surgical interventions. In total, 63% of patients desired CCE for their next colonoscopy. CCE was relatively safe, well tolerated, and useful for detecting colorectal lesions when adequate bowel preparation was made.
Read full abstract