Ventricular assist devices (VADs) are used to bridge pediatric patients to heart transplantation. Paracorporeal VADs require the placement of cannulas, which can create an environment for infections. We examined cannula infections in pediatric VAD patients and the role of nutritional status. This retrospective study (2005-2021) included patients <20 years old on VAD support using Berlin Heart EXCOR® cannulas. Cannula infections were defined by a positive culture and need for antibiotic therapy. Malnutrition was defined using the American Society of Parenteral and Enteral Nutrition guidelines as well as the Michigan MTool. There were 76 patients with a median age at implant of 0.9 years (IQR 0.4, 3.6), 50% male, with 73.7% having non-congenital heart disease. More than one-quarter (26.3%) of patients developed a cannula infection. Higher pre-implant weight (OR = 1.93, p = 0.05), creatinine (OR = 1.02, p = 0.044), and pre-albumin (OR = 15.79, p = 0.025), as well as duration of VAD support (OR = 1.01; p = 0.003) were associated with increased odds of developing a cannula infection. There was no difference in the malnutrition parameters between those with and without an infection. Further exploration in a larger cohort is needed to see whether these associations remain and if the incorporation of objective measures of nutritional status at the time of infection are predictive.