Abstract

Infection of the percutaneous site of a ventricular assist device (VAD) is a challenging complication. We report our experience with crystal violet Solbase (Nihon University crystal violet method) for prevention of driveline or cannula infections in VAD patients. The crystal violet method was used in 10 patients (prophylaxis in nine and treatment in one). Eight patients had an extracorporeal VAD (Nipro) and two had an implantable VAD (Heart Mate II). The infection-free period was 4-623 days (mean: 144.2 ± 222.9 days). All eight patients with an extracorporeal VAD died, while the two patients with an implantable VAD (Heart Mate II) survived. Infection was improved in a patient with MRSA, and the results of bacteriological examination were always negative in the patients receiving prophylaxis. The two patients with an implantable VAD had no infection for 2 and 20 months after implantation. These findings suggest that the Nihon University crystal violet method is effective for prevention and treatment of driveline or cannula infections in patients with a VAD.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.