AbstractThe principles of differential thermal analysis and thermogravimetric analysis are outlined and two examples of their application to autoclaved calcium silicate products are given. The proportions of calcium hydroxide and calcium carbonate in samples can be estimated. Useful information on calcium hydrosilicate binding materials can be obtained in experiments where the number of variables is strictly controlled.