The aim of the present study was to assess the performance and complementarity of methods capable of both quantifying furan, 2-Methylfuran (2-MF) and 3-Methylfuran (3-MF) in infant foods, but also to comprehensively explore other furan derivatives. It is more particularly a question of validating and comparing the couplings of the two headspace extraction methods most used for the analysis of furan compounds − Headspace Solid Phase Microextraction (HS-SPME) and Static HeadSpace (SHS) – with gas chromatography hyphenated to a high-resolution mass detector (Q Exactive-Orbitrap MS) which allows both targeted quantification and suspect screening. Firstly, the accuracy profile approach was implemented to assess, validate and compare HS-SPME- and SHS-GC-Q Exactive-Orbitrap MS for the quantification of furan in two model infant foods, apple puree and first infant formula. SHS-GC-Q Exactive-Orbitrap MS, showed better accuracy (uncertainty < 17.2 % vs 22.5 % for HS-SPME GC-Q Exactive-Orbitrap MS) and better sensitivity (LOQ < 2.8 vs LOQ < 4.0 µg/kg) over a broader validation range (2–100 µg/kg vs 5–100 µg/kg in apple puree). Secondly, SHS-GC-Q Exactive-Orbitrap MS was assessed and validated by accuracy profile for the quantification of 2-MF and 3-MF, with performance close to those for furan except for 3-MF in apple puree. Thirdly, SHS-GC-Q Exactive-Orbitrap MS was used to quantify the levels of these compounds in 20 commercial samples (n = 3) belonging to the four main categories of infant food (infant formulae, fruit purees, infant cereals, vegetable/fish baby meals). Furan was quantified in 75 % of the samples, with maximum levels in the vegetable/fish-based infant foods (up to 127 µg/kg) while 2-MF and 3-MF were quantified in 45 % and 15 % of products respectively, with maximum levels of 14.1 µg/kg in follow-on formula 3rd age and 9.2 µg/kg in apple puree. Finally, SHS- and HS-SPME-GC-Q Exactive-Orbitrap MS data of the 20 infant products were processed in suspect screening mode using Compound DiscovererTM software. Coupling with HS-SPME, it made it possible to identify 13 additional furan derivatives, i.e. 5 more than with SHS. The relevance and safety status of the compounds identified are discussed.
Read full abstract