ObjectiveTo investigate the technical periprocedural and midterm outcomes of endovascular repairs with multibranched endovascular repair or iliac branch devices combined with a new self-expanding covered stent. MethodsThe COvera in BRAnch registry is a physician-initiated, multicenter, ambispective, observational registry (ClinicalTrials.gov Identifier: NCT04598802) enrolling patients receiving a multibranched endovascular repair or iliac branch devices procedure mated with Bard Covera Plus (Tempe, AZ) covered stent, designed to evaluate the outcomes of the covered stent mated with patient-specific and off-the-shelf branched stent graft. Primary end points were technical success, branch instability, and freedom from aortic and branch-related reintervention within 30 days and at follow-up. Preoperative characteristics, comorbidities, and outcomes definitions were graded according to the Society for Vascular Surgery reporting standards. ResultsTwo hundred eighty-four patients (76 years; range, 70-80 years; 79% males) in 24 centers were enrolled for a total of 708 target vessels treated. The covered stents were mated with an off-the-shelf graft in 556 vessels (79%) and a custom-made graft in 152 (21%). Three hundred seven adjunctive relining stents in 277 vessels (39%) were deployed, of which 116 (38%) were proximal, 66 (21%) intrastent, and 125 (41%) distal. Adjunctive relining stent placement was more frequent when landing in a vessel branch instead of the main trunk (59% vs 39%; P = .031), performing a percutaneous access (49% vs 35%; P < .001), using a stent with a diameter of 8 mm or greater (44% vs 36%; P = .032) and a length of 80 mm or greater (65% vs 55%; P = .005), when a post-dilatation was not performed (45% vs 29%; P < .001) and when an inner branch configuration was used (55% vs 35%; P < .001). Perioperative technical bridging success was 98%. Eight patients (3%) died in the perioperative period. Two deaths (1%) were associated with renal branch occlusion followed by acute kidney injury and paraplegia. Follow-up data were available for 638 vessels (90%) at a median of 32 months (Q1, Q3, 21, 46). Branch instability was reported in 1% of branches. Forty-six patients (17%) died during follow-up, nine (3%) of them owing to aortic-related causes. Primary patency rates at 1, 2, and 3 years were 99% (581/587), 99% (404/411), and 97% (272/279), respectively. Branch instability was associated with patient-specific devices (9% vs 4%; P = .014) and intrastent adjunctive stent placement (12% vs 2%; P = .003), especially when a bare metal balloon-expandable stent was used (25% vs 3%; P < .001). ConclusionsThe use of this new self-expanding covered stent mated with branched endografts proved to be safe and feasible with high technical procedural success rates. Low rates of branch instability were observed at midterm follow-up. Comparative studies with other commercially available covered stents are warranted.