There are limited data available on the development of arrhythmias in patients at risk of high-degree atrioventricular block (HAVB) or complete heart block (CHB) following transcatheter aortic valve replacement (TAVR). This study aimed to explore the incidence and evolution of arrhythmias by monitoring patients at risk of HAVB or CHB after TAVR using smartwatches. We analyzed 188 consecutive patients in the prospective SMART TAVR (smartwatch-facilitated early discharge in patients undergoing TAVR) trial. Patients were divided into 2 groups according to the risk of HAVB or CHB. Patients were required to trigger a single-lead electrocardiogram (ECG) recording and send it to the Heart Health App via their smartphone. Physicians in the central ECG core lab would then analyze the ECG. The incidence and timing of arrhythmias and pacemaker implantation within a 30-day follow-up were compared. All arrhythmic events were adjudicated in a central ECG core lab. The mean age of the patients was 73.1 (SD 7.3) years, of whom 105 (55.9%) were men. The mean discharge day after TAVR was 2.0 (SD 1.8) days. There were no statistically significant changes in the evolution of atrial fibrillation or atrial flutter, Mobitz I, Mobitz II, and third-degree atrial ventricular block over time in the first month after TAVR. The incidence of the left bundle branch block (LBBB) increased in the first week and decreased in the subsequent 3 weeks significantly (P<.001). Patients at higher risk of HAVB or CHB received more pacemaker implantation after discharge (n=8, 9.6% vs n=2, 1.9%; P=.04). The incidence of LBBB was higher in the group with higher HAVB or CHB risk (n=47, 56.6% vs n=34, 32.4%; P=.001). The independent predictors for pacemaker implantation were age, baseline atrial fibrillation, baseline right bundle branch block, Mobitz II, and third-degree atrioventricular block detected by the smartwatch. Except for LBBB, no change in arrhythmias was observed over time in the first month after TAVR. A higher incidence of pacemaker implantation after discharge was observed in patients at risk of HAVB or CHB. However, Mobitz II and third-degree atrioventricular block detected by the smartwatch during follow-ups were more valuable indicators to predict pacemaker implantation after discharge from the index TAVR. ClinicalTrials.gov NCT04454177; https://clinicaltrials.gov/study/NCT04454177.
Read full abstract