Objective: To evaluate a fixed UV-C light emitting device for its antimicrobial effectiveness in the disinfection of distinct surfaces and its antifungal effectiveness on air quality in the hospital environment. Methods: This quasi-experimental study was conducted in a hospital inpatient unit, in which a six-stage air Biosampler (Andersen®) was used for air analysis. In the evaluation of surfaces, three suspensions of microorganisms (Acinetobacter sp. multidrug-resistant, Escherichia coli, and KPC-producing Klebsiella pneumoniae) were used to contaminate the environment. In both evaluations, pre- (control) and post-activation of UV-C light (test) collections were made. Results: In the air evaluation, an important reduction was observed in the colony count after irradiation with UV-C light, and pathogenic or toxigenic fungi were not found in either of the two moments. Regarding the disinfection of surfaces, no bacterial growth was observed after the application of UV-C light, showing 100% bacterial inactivation under the tested conditions. Conclusion: The use of fixed UV-C light emission technology was effective and can be considered a promising intervention for hospital surface disinfection protocols.