Abstract

X-ray induced electron and hole trapping properties have been investigated in SIMOX buried oxides of different processes, including standard and supplemental implantation oxides, as well as new thin and ultra-thin oxides. The effect of the substrate bias applied during irradiation is studied, and then used to extract both hole and electron trapping parameters. The results demonstrate that varying the oxygen implantation conditions has very little effect on the radiation induced behavior of the material. They show that the charge trapping properties of the buried oxide are related to the ultra high temperature anneal performed on the confined oxide layer, and confirm that the post implantation anneal is the most critical part of the SIMOX process.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.