Abstract
Recoil-ion charge distributions produced in single collisions of 8 MeV/u Kr13+ and Kr32+ projectiles with Xe atoms have been measured using time-of-flight spectroscopy. The post-collision charge states of the projectile ions were determined by magnetic dispersion onto a position sensitive microchannel plate detector. The recoil-ion distributions for ionization accompanied by electron loss from Kr13+ projectiles were bell-shaped with averages that ranged from 7.4 for 1-electron loss to 13.9 for 5-electron loss. The recoil-ion distributions for ionization accompanied by electron capture to Kr32+ projectiles were also bell-shaped, but had much higher average charges that ranged from 20.4 for 1-electron capture to 28.5 for 4-electron capture. The large difference in the average charges produced in the two types of collisions is mainly attributable to charge magnification by Auger decay. A simple model quantitatively explains the variation of the capture-ionization charge distribution width and average charge as a function of the number of captured electrons.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Zeitschrift f�r Physik D Atoms, Molecules and Clusters
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.