Abstract

The X-mode radial correlation reflectometry diagnostic on JET has long suffered from strong signal attenuation in the original transmission lines. To reach higher performances, new low-attenuation corrugated circular waveguides and a new cluster of six antennas have been successfully installed in Autumn 2005. The increase of the signal-to-noise ratio using these new transmission lines is found to be on the order of magnitude of 20 dB, thus enabling good quality of reflectometry measurement. With the benefit of this improvement, first X-mode reflectometry measurements of density fluctuations in the core region of the JET plasma are reported in this article.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.