Abstract

The purpose of this study was to compare the 1,2 with a novel 2R portal in terms of proximity to critical structures. Wrist arthroscopy was performed on 8 fresh frozen cadavers via the 1,2 and 2R portals. External anatomy was then dissected under loupe magnification. The closest distance between the portals and surrounding anatomical structures was measured in millimeters using digital calipers. The 1,2 portal was significantly closer to radial artery and first extensor compartment tendons than the 2R portal. The radial artery was on average 1.32 mm from the 1-2 portal and 14.25 mm from the 2R portal. The 2R portal was significantly closer to the second and third extensor compartment tendons. The closest branch of the superficial branch of the radial nerve (SBRN) was on average 2.04 mm from the 1-2 portal and 7.59 mm from the 2R portal, but this was not statistically significant. We advocate using the 2R portal preferentially to the 1,2 portal when treating radial sided wrist pathology to decrease the risk of iatrogenic radial artery and SBRN injury.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.