Abstract

The wood behavior varies with temperature, which has a negative effect, being verified by progressive properties degradation. After fire exposure, it is possible to measure the wood char layer and the remaining resistant cross-section area. Based on numerical models and analytical equations, it is possible to study the protection level of wood connections, during fire exposure, and evaluate wood and steel dowels temperature fields in conjunction. The main objective of this work is to verify the fire resistance of unprotected (W-W-W) wood connections and compare the results with protected connections using gypsum plasterboard. According Eurocode 5, part 1-2 the connections could be protected by the addition of wood paneling, wood-based panels or gypsum plasterboard type A, H or F. To obtain conclusions according the application of different type of gypsum plasterboard in the designed W-W-W connections in different densities material, numerical models were building to verify the level of protection in fire action. Design methods require the use of analytical methodologies and computational modelling to predict the fire exposure and the components capacity to resist to this action. Results of the temperature field in the studied connections under fire will be presented, with the measured char layer in unprotected members and comparing the protected efficiency with different types of gypsum plasterboard.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.