Abstract

The main objective of this work is to present a numerical model to predict the effect of wood density in unprotected wood connections with an internal steel plate (wood–steel–wood), when comparing with the same connections using passive protection with gypsum plasterboard, submitted to fire conditions. Wood–steel–wood connections are made of four wood members, two on each side, with an internal steel plate that connects the pieces using steel dowel fasteners. First, analytical methodologies according to Eurocode 5 part 1-1 were used to design the connections at room temperature. After that, to predict the fire exposure and the connection ability, a numerical model was performed which permits to compare the fire resistance in wood–steel–wood connections without and with passive protection following the Eurocode 5 part 1-2. Results of the temperature and the wood char layer depth were compared using three different wood densities. The evolution of the charring rate was calculated in different locations of the connections and compared with the analytical value proposed by the Eurocode 5 part 1-2.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.