Because wind power is connected to the grid on a large scale, frequency fluctuation in the power grid, which is defined as a system safety risk to the power grid, occurs from time to time. According to the grid code rules of China, wind turbines are required to be equipped with primary frequency modulation or inertia response control capability, which are used to support the safe and stable operation of the power grid. During the traditional frequency modulation process of the wind turbine, power limiting operation or pitch angle reservation is generally adopted to ensure that the reserved energy can be released at any time to support the frequency change in the power grid. However, the frequency support method leads to a large loss of power generation, and does not consider the coordination between mechanical load characteristics control and primary frequency modulation. In this paper, a mechanical load optimization control strategy for a wind turbine during the primary frequency modulation process, based on LIDAR (light detection and ranging) feed forward control technology, is proposed and verified. Through LIDAR feed forward control, the characteristics of incoming wind speed can be sensed in advance, with the consequence that the wind turbine can participate in, and actively control, the primary frequency modulation procedure. According to the characteristics of incoming wind, for instance the amplitude and turbulence, simultaneously, the size of the reserved pitch angle can be adjusted in real time. This kind of method, coordinating with the mechanical load of the wind turbine, can be used to reduce both the ultimate load and fatigue damage as much as possible. Finally, the mechanical load characteristics of the wind turbine with and without the control strategy are compared and studied through simulation. The research results show that the load optimization control strategy based on LIDAR feed-forward control technology can effectively reduce the fatigue and ultimate loads of the wind turbine while supporting the frequency change in the power grid; especially for the fatigue load of tower base tilt and roll bending moments, the reducing proportion will be about 4.3% and 6.3%, respectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.