Abstract

Peak bending moments are compared for a set of steel portal frames of industrial buildings in an open terrain calculated using database-assisted design (DAD) techniques and ASCE 7-05 Standard plots. The comparisons indicate that, depending on the building dimensions, the peak bending moments at the knee based on DAD techniques are generally larger by 10–30% than their counterparts based on the ASCE 7-05 plots. (In one case with a relatively steep roof slope of 26.6° the discrepancies exceed 70%.) For the buildings considered, the discrepancies increase with increasing roof slope and with increasing eave height.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.