Abstract

With increasing evidence of adverse health effects of lower lead levels (below 10 µg/dL in whole blood), studies on novel internal dose biomarkers are needed. This study aimed at: (1) assessing the lead exposure by measuring this element in whole blood (Pb-blood), serum (Pb-serum), and 3 different types of saliva: whole (Pb-whole-saliva), submandibular/sublingual (Pb-sub-saliva) and parotid saliva (Pb-parotid-saliva); (2) correlating Pb-blood with Pb-serum; and (3) relating Pb-blood and Pb-serum with the lead found in the different salivas. The study population included 444 children aged 6 to 8 years attending 4 government schools in the district of Campos Eliseos, in Ribeirao Preto, Sao Paulo State, Brazil. Whole blood, serum, parotid, submandibular/sublingual (“sub-saliva”), and whole saliva were collected in trace element-free tubes. Lead concentrations were determined by inductively coupled plasma-mass spectrometry (ICP-MS). Median Pb-blood and Pb-serum were 2.1 µg/dL and 0.4 µg/L, respectively. Ten percent of the children had Pb-blood between 4.0 and 9.4 µg/dL. Boys showed higher Pb-blood than girls (2.3 vs. 2.0 µg/dL, p < 0.0003). Lead concentrations in whole, sub, and parotid saliva were 1.7, 1.4, and 1.3 µg/L, respectively. No significant correlations were found between Pb-blood and Pb-serum, between Pb-blood and lead in the 3 different salivas, or between Pb-serum and Pb-whole-saliva or Pb-sub-saliva. However, there was a weak statistically significant correlation between Pb-serum and Pb-parotid-saliva. In conclusion, the mean Pb-blood concentration was 2.4 µg/dL, with 10% of the children exhibiting Pb-blood between 4.0 and 9.4 µg/dL. Boys presented higher Pb-blood. Results suggest that Pb-blood has no correlation with Pb-serum or lead in the 3 different salivas collected here. A weak but statistically significant correlation between Pb-serum and Pb-parotid-saliva was found. Our results also point to the need for carrying out more studies on sources of exposure and lead levels in children in Brazil.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.