Abstract
BackgroundThe World Health Organization (WHO) cone bioassay is a key method used to evaluate the bioefficacy of long-lasting insecticidal nets (LLINs) used for malaria control. These tests also play an important role in LLIN product prequalification and longitudinal monitoring. Standardization of these assays is therefore important. While many parameters for WHO cone bioassays are defined in the respective WHO guidelines, others are not. One of these undefined parameters is the exact configuration of the bioassay boards. In cone bioassays, LLIN samples are pinned onto a bioassay board for testing. Anecdotal evidence suggests that bioassay boards with holes behind the LLIN samples lead to greater exposure to insecticide, as the mosquitoes are ‘forced to stand on the net material’. This may increase the key assay outcomes of 60 min knockdown (KD60) and 24 h mortality (M24). The present study tested this hypothesis in two facilities using two fully susceptible mosquito colonies.MethodsWHO cone bioassays were performed using bioassay boards with holes and boards without holes in parallel, following WHO guidelines. Five brands of LLINs with four new and unwashed whole net samples per brand were used (total of n = 20 whole nets). Five pieces per whole net sample were prepared in duplicate resulting in a total of n = 100 pairs.Knock-down (KD) was recorded in 10 min intervals within the first hour after exposure and mortality was recorded at 24 h. Assays with Anopheles farauti were done at the Papua New Guinea Institute of Medical Research (PNGIMR) and assays with Aedes aegypti were done at James Cook University, Australia.ResultsResults varied not only with bioassay board configuration but also with mosquito colony. In particular, with An. farauti, a significantly higher M24 was observed when boards with holes were used, while this was not observed with Ae. aegypti. WHO cone bioassay results were systematically biased between the two facilities such that the use of An. farauti at PNGIMR predicted higher KD60 and M24.ConclusionThe present study highlights the need for further harmonization of WHO cone bioassay methodology. Parameters such as bioassay board configuration and mosquito species systematically affect the observations, which impedes generalizability of WHO cone bioassay outcomes.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.