Abstract

AbstractBackgroundNeurite Orientation Dispersion and Density Imaging (NODDI) is becoming increasingly common as multiband acceleration becomes available for clinical scanning, but fitting the model can be extremely slow. Since the release of the original MATLAB implementation in 2012, three alternatives have become popular: Accelerated Microstructure Imaging via Convex Optimization (AMICO), the Microstructure Diffusion Toolbox (MDT), and the CUDA Diffusion Modelling Toolbox (cuDIMOT). They accelerate fitting through reformulation and/or using GPUs, but the implementation differences raise the question of which approach is best. To our knowledge all previous comparisons lacked knowledge of the true values and used the original implementation as the nominally correct one, with in vivo data. We remedy that using simulations with known NODDI values, in addition to in vivo scans.MethodWe created a software phantom with Neurite Density Index (NDI) values linearly increasing from 0.1 to 1.0 in x, Orientation Dispersion (ODI) from 0 to 1 in y, and Isotropic water Volume Fraction (ISOVF) from 0 to 0.9 in z. We simulated five scans using the ADNI3 advanced diffusion MRI protocol. The phantom had 20 voxels in each direction, and the fiber bundle principal direction randomly varied between the simulations. The simulations were fit by the original, AMICO, MDT, and cuDIMOT implementations, and root mean square errors were calculated as shown in Table 1. A discrepancy measure was also calculated using the brain voxels of three in vivo human scans acquired using the same protocol on a Siemens Prisma, substituting the original implementation’s values for the truth since the latter is unknown for in vivo scans.ResultcuDIMOT had the least error (for ODI < 0.8) and was fastest. The original implementation was a close second in accuracy but much slower. cuDIMOT’s ODI underestimation can be corrected with a transfer function in the noise‐free case, but that approach fails with actual scans.ConclusionThe original or cuDIMOT implementations should be used, with cuDIMOT the favorite when at least one CUDA‐capable GPU is available and the number of scans are large. Correcting cuDIMOT’s ODI underestimation using a different initialization or form of Dawson’s integral should be investigated.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.