Abstract
BackgroundEsophageal cancer treatment requires large radiation fields due to the deep location of the esophagus in the mediastinum and the high incidence of radial spread. There is no optimal radiation technique to ensure appropriate target coverage and minimal dose to all normal structures.MethodsFifteen consecutive cases of locally advanced esophageal cancer treated with radical chemoradiation (CRT) were analyzed. The total prescribed dose was 50.4 Gy in 28 fractions. A total of 60 plans were generated for analysis, including four different methods for each case. Method 1 consisted of a four-field conformal technique; method 2 was a two-plan technique (antero-posterior (AP), postero-anterior (PA), two posterior oblique fields (RPO and LPO)); method 3 was a three-field conformal technique (AP, LPO, RPO); and method 4 was a volumetric modulated arc radiotherapy (VMAT) technique. Dose ratios were calculated using the minimum, maximum, mean, and median doses of methods 2-4 over the dose of method 1. Ratios for the planning target volume (PTV) and to surrounding organs were analyzed.ResultsThe mean PTV dose ratio ranged from 0.994 to 1.048 (SD = 0.01) representing an adequate target coverage for all techniques based on an analysis of variance (ANOVA). For the lungs, method 2 had the lowest lung V20 with a ratio of 0.861 (SD = 0.12), whereas method 3 had the highest with 1.644 (SD = 0.14). For the heart, method 3 had the lowest heart V40 with a mean dose ratio of 0.807 (SD = 0.09), whereas method 2 had the highest with 1.160 (SD = 0.11). For the liver, method 2 had the lowest V30 with a mean ratio of 0.857 (SD = 0.1) whereas method 4 had the highest with 1.672 (SD = 0.48). For the spinal cord, method 3 had the lowest mean dose ratio of 0.559 (SD = 0.09) whereas method 2 had the highest with 1.094 (SD = 0.04).ConclusionThe four radiation techniques for esophageal cancer treatment were appropriate for target coverage. Method 2 had the most organ-sparing effect for the lungs and liver, and method 3 for the heart and spinal cord. VMAT did not add any significant sparing. A case-by-case decision should be made based on the patient’s comorbidities.
Highlights
Esophageal cancer is an aggressive disease with half of the patients presenting at a locally advanced stage [1,2]
1 consisted of a four-field conformal technique; method 2 was a two-plan technique (antero-posterior (AP), postero-anterior (PA), two posterior oblique fields (RPO and LPO)); method 3 was a three-field conformal technique (AP, LPO, RPO); and method 4 was a volumetric modulated arc radiotherapy (VMAT) technique
The mean planning target volume (PTV) dose ratio ranged from 0.994 to 1.048 (SD = 0.01) representing an adequate target coverage for all techniques based on an analysis of variance (ANOVA)
Summary
Esophageal cancer is an aggressive disease with half of the patients presenting at a locally advanced stage [1,2]. Treatment of locally advanced esophageal cancer requires a multimodal approach that includes neoadjuvant chemoradiation (CRT) and resection for resectable disease, and radical concurrent CRT for unresectable disease. In both settings, radiation treatment volumes are large to account for the well-described tendency of esophageal cancer to extend submucosally in the longitudinal direction over a considerable distance [4]. Toxicities of grade 3 or more are reported in up to 15% of the patients during this treatment, which can lead to a possible delay in treatment [5,6] These challenges raise the question of what is the optimal radiation technique that limits toxicities while delivering the appropriate target coverage. There is no optimal radiation technique to ensure appropriate target coverage and minimal dose to all normal structures
Published Version (Free)
Talk to us