Abstract

Three-dimensional (3D) preoperative planning software for reverse total shoulder arthroplasty (rTSA) has been implemented in recent years in order to increase accuracy, improve efficiency, and add value to the outcome. A comprehensive literature review is required to determine the utility of preoperative 3D planning software in guiding orthopedic surgeons for implant placement in rTSA. We hypothesize that implementation of 3D preoperative planning software in the setting of rTSA leads to high concordance with minimal deviation from the preoperative plan. A comprehensive and iterative literature review was conducted according to the Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA) using the PubMed, Embase, OVID Medline, Scopus, Cinahl, Web of Science, and Cochrane databases for original English-language studies evaluating the impact of preoperative planning software usage on rTSA outcomes published from January 1, 2000, to present. Blinded reviewers conducted multiple screens. All included studies were graded based on level of evidence, and data concerning patient demographics and postoperative outcomes were extracted. Nine articles met inclusion criteria (1 level II, 3 level III, and 5 level IV articles), including 415 patients and 422 shoulders. Of the patients who underwent rTSA, 235 were female and 140 were male, although 3 studies (n=40) did not report sex breakdowns for rTSA patients. The average age was 72.7 years. Four studies (79 shoulders) reported implant final position as mean deviation from planned version and planned inclination. Six studies (n=236) reported screw angle deviation, fixation, length, and concordance. Concordance with the preoperative plan was measured in 3 studies (n=178), resulting in complete concordance of 90% (n=100), arthroplasty type concordance (rTSA vs. TSA) of 100% (n=100), and glenosphere size concordance between 93% (n=100) and 88% (n=76). For screw length concordance, baseplate screw matched by 81% (n=76) and 100% (n=2), and upper (n=35) and lower (n=35) screw length concordance was observed as 74% and 69%, respectively. The use of preoperative planning (n=178) was associated with low deviation from preoperative plan, more 2-screw fixations, and longer average screw length in comparison with an unplanned cohort. The use of preoperative planning software in the setting of rTSA results in minimal deviation from preoperative plan. High levels of concordance in screw angle, screw length, and glenosphere size were observed. Further prospective studies should be conducted to further substantiate these results.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call