Abstract

To the Editor, In the recent review of the British Thoracic Society guidelines for the investigation of unilateral pleural effusion in adults, 1 there was no mention of biochemical analysis of pleural fluid for the diagnosis of parapneumonic pleural effusions (PPE). PPE is an exudate associated with pneumonia, abscess or bronchiectasis, called empyema when it contains pus. 2 The biochemical analysis of pleural fluid is important for the diagnosis of PPE. The aim of our study was to determine the accuracy of biochemical parameters of pleural fluid for the diagnosis of PPE, using receiveroperating characteristic (ROC) techniques by analysing the area under the ROC curve (AUC) and determining the optimal cut-off value. We studied 207 pleural fluids obtained anaerobically by thoracocentesis using gasometry syringes in 110 men and 97 women aged between 1 and 90 y (average 58 y), from June 2005 to July 2006. The following variables were analysed: protein, glucose, lactate dehydrogenase (LDH), lactate and amylase by INTEGRA 400 (Roche Diagnostics S.L w , Barcelona, Spain), adenosine deaminase (ADA) by Modular P (Roche Diagnostics S.L w ), pH and pCO2 by gasometer IL-1620 (Izasa S.A. w , Barcelona, Spain), and the aetiological diagnosis of pleural effusion discharged from hospital after evaluating clinical and radiological data and laboratory tests. Protein was analysed by Biuret reaction, glucose by enzymatic reference method with hexokinase, LDH, lactate, amylase and ADA by enzymatic colorimetric methods according to the International Federation of Clinical Chemistry. The serum LDH reference range was 135 –225 U/L. The diagnosis of PPE required an acute febrile illness with purulent sputum and pulmonary infiltrates in association with a pleural effusion or positive pleural fluid culture or positive pleural fluid Gram stain or purulent pleural fluid. Pleural fluids were classified into two groups: PPE and non-PPE. Statistical analysis was performed using the software Medcalc w . Forty-six of 207 pleural fluids studied were PPE (14 uncomplicated PPE, eight complicated PPE and 24

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.