Abstract

The water-gas shift reactor in the fuel processing unit of a fuel cell system has the vital function of reducing the concentration of CO in the reforming reactor's product gas to values of between 1.0 and 1.5 vol% in order to protect the anodic catalyst from becoming irreversibly poisoned. This paper presents Jülich's recent development in this field, specifically the WGS 6 in the 5 kWe class. The WGS 6 is characterized by a fundamentally new concept for arranging high temperature and low temperature shift stages. Both stages are now coaxially integrated in one joint casing to provide higher values for the power density and specific power, whereas in earlier reactor generations, these stages are arranged in two separate, parallel housings. In addition, this contribution presents results from a long-term experiment for 5000 h on stream with WGS 6 and discusses the temporal trends of the product gas composition and reactor temperatures across this timespan. For this experiment, the inlet gas stream is produced by an autothermal reformer, which is installed upstream of the WGS 6.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.