Abstract

Banda Aceh city is an earthquake-prone area. One is the phenomenon that a magnitude 9,3 Mw and subsequent tsunami wave occurred in 2004. The incident caused casualties and damage to facilities including educational facilities such as school buildings. After the 2004 Tsunami, affected school was rebuilt in same location as before, therefore necessary to conduct an assessment of school building to ensure safety and comfort of learning process in affected area. The purpose of this study was to determine structure capacity of reinforced concrete school building structure toward earthquake and Tsunami in Banda Aceh, so it can see contruction vulnerability based on table of damage state. Objects in this study was a typical two-story reinforced concrete school buildings in Banda Aceh. The chosen building were SDN 48 and SDN 8. Structures were modelled by using SAP2000 software. Earthquake load data using the 2004 Sumatera-Andaman earthquake and Puskim earthquake-predictions which were analyzed using pushover method, and tsunami loads based on the height of inundation at location of school building. As a results, it has been developed capacity curve and spectrum capacity curve to determine damage limit and probability due to earthquake and tsunami hazards. It was found that based on spectrum capacity curve both school buildings in slight damage, while based on fragility curve it was found that both school building have a risk of light damage and moderate damage. Based on tsunami load, it has been found that both school building has inter-story drift that exceeds allowable limit, and based on tsunami fragility curve both school building were predicted complete damage.

Highlights

  • Banda Aceh city is an earthquake-prone area

  • Another reason for choosing this school building is because it is relatively close to the beach and the 2004 tsunami inundation height was recorded at that location

  • 4.1 Conclusions Based on the results of the discussion and data analysis carried out, a conclusion is drawn regarding the study of the vulnerability of school buildings with reinforced concrete construction in Banda Aceh City to earthquake and tsunami hazards as follows: 1. Based on the results of structural behavior due to Sumatera-Andaman earthquake 2004 and indonesia seismic hazards map 2017 earthquake source map at SDN 48 and SDN 8, the value of inter story drift is greater than the inter story drift permit levels, the building does not meet the provisions of SNI 1726-2019 2

Read more

Summary

Introduction

Banda Aceh city is an earthquake-prone area. This is because Banda Aceh City is located between two fault segments, namely the Aceh fault segment and the Seulimuem fault segment that still active [1]. The purpose of this study was to determine structure capacity of two-story reinforced concrete school building structure toward earthquake and Tsunamis in Banda Aceh. As an object in this study was a typical two-story reinforced concrete school building structure that are mostly found in the Banda Aceh city. The typical structure of a school building in Banda Aceh city is a two-story reinforced concrete damage or light damage, while based on the fragility curve that has been developed the school buildings have a risk of light damage and moderate damage. In the calculation due to the tsunami load, the school building has an inter-story drift that exceeds allowable limit and based on tsunami fragility curve that has been developed, SDN 48 and SDN 8 buildings are predicted to be complete damage

Objectives
Methods
Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.