Abstract

In this paper, we studied partial discharge (PD) inception characteristics and V-t characteristics of PD inception in liquid nitrogen (LN/sub 2/)/polypropylene laminated paper (PPLP/sup /spl reg//) composite insulation system for high temperature superconducting (HTS) cable. Experimental results revealed that the magnitude of initial PD was in the range of 2.0-30 pC irrespective of butt gap condition and the initial PD was generated at the first and third quadrant of voltage phase. PD inception electric field strength (PDIE) without butt gap was 5-10% higher than that with butt gap and thicker butt gap gave larger PDIE drop. Moreover, PDIE with butt gap depended on the butt gap thickness and the number of PPLP/sup /spl reg// layers. The reason is explained by the existing probability of weak points of electrical insulation at butt gap. Finally, lifetime indices n of V-t characteristics at PD inception were obtained as 80-100 irrespective of butt gap condition. These values showed enough flat characteristics of V-t phenomena of electrical insulation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.