Abstract
We discuss partial discharge (PD) inception characteristics and V-t characteristics of PD inception in liquid nitrogen (LN/sub 2/)/polypropylene laminated paper (PPLP/sup /spl reg//) composite insulation system for high temperature superconducting (HTS) cable. Experimental results revealed that the magnitude of initial PD was in the range of 2.0-30 pC irrespective of butt gap condition and the initial PD was generated at the first and third quadrant of the voltage phase independent pressurized condition of LN/sub 2/. Furthermore, life time indices n of V-t characteristics at PD inception were experimentally identified and the dependency on the pressure of LN/sub 2/ was clarified.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.