Abstract

Power grid analysis is a challenging problem for modern integrated circuits. For 3-D systems fabricated using stacked tiers with TSVs, traditional power grid analysis methods for planar (2-D) circuits do not demonstrate the same performance. An efficient IR drop analysis method for 3-D large-scale circuits, called 3-D voltage propagation method, is proposed in this paper. This method is compared with another widely used power grid analysis method, with preconditioned conjugated gradients. Simulation results demonstrate that the proposed method is more efficient for the IR drop analysis of large size 3-D power grids. Speedups between 10× to 20× over the preconditioned conjugated gradients method are shown.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.