Abstract

ASTM Committee E37 on Thermal Measurements published a new test method 'Standard Test Method for Volatility Rate by Thermogravimetry' in June 1999 with the designation E 2008. This approach to assessing volatility utilizes an extension of the pinhole technology previously employed by E37 for vapor pressure determinations using differential scanning calorimetry (ASTM E 1782). After publication of the test method E 2008, an Interlaboratory Study was undertaken to develop a 'Precision and Bias' statement to be assigned with the test method. This paper provides some background data that supports the claim that E 2008 is generally insensitive to experimental conditions other than temperature. The Interlaboratory Study showing the statistical review is also discussed.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.