Abstract

In this paper, (Part II of a two-part study), an investigation of void fractions for condensing flows of refrigerant R-134a in minichannels is presented. Custom digital image processing techniques were used to quantitatively analyze these flows in transparent minchannel geometries (square, rectangular and circular) with 2 < Dh < 4.91mm. A total of 140 void fraction values in the intermittent flow regime (slug and plug flow), the wavy flow regime, and an intermittent-wavy overlap region were measured. A new model was developed based on these measured values and predicts void fraction better than correlations from the literature.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.