Abstract
This paper addresses the issues of monitoring and diagnostics of flow processes in gravitational flows of friable materials within large-scale silos. The author shows how the electrical capacitance tomography (ECT) may be used for monitoring large-scale industrial reactors dedicated for dense granular flow. The ECT sensors under investigation are specially designed for large-scale measurements and accompanied by a dedicated measurement protocol. The proposed ECT sensor allows visualizing, in form of 3-D image, material concentration distribution inside silo wall area for 1.5 m silo container. The developed method provides possibility of analyze effective transition point, boundary between stagnant zone and flowing material.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.